Home / Nurse call

Hospital and aged care nurse call systems

An Australian nurse call system, built this decade.

Southerly Nurse Call is a complete nurse call system for Australian hospitals and residential aged care — room, ward and head end — designed to AS 3811:2026, with reporting, clinical messaging and room sensing built in. It installs new, or runs over the legacy system a hospital already owns so the move happens ward by ward. Built by a team that has kept Victorian hospital call systems running since 2014.

The system

  1. 1
    A patient presses the call pointCP-02 · light goes on via LR-01 · supervised bus
  2. 2
    The Edge Node takes itEN-01 · lights, displays, Quiet Mode, inputs
  3. 3
    The Enterprise Gateway records itLive board, response time, uptime, BACnet
  4. 4
    It reaches the right phoneOlinqua / Ascom over TAP · heartbeat-supervised
  5. 5
    The report shows it next morningBy ward, shift and call type · PDF for the DON

Southerly Nurse Call

One system from the bedside to the phone in a nurse's pocket — with displays, clinical messaging, room sensing and reporting built in, not bolted on. Designed to AS 3811:2026.

Install it newSoutherly hardware in the room, on the ward and at the head end — supplied through accredited partners.
Or run it over a legacy systemThe gateway reads the old controller; rooms move ward by ward. No big-bang cutover. How migration works →
—

Components

Every part of the system is a product in its own right, with a datasheet, a status and a model code. Nothing here is a concept drawing: status pills say what's shipping, what's in pilot and what's still on the bench.

RESPONDSoftware

Respond

Nurse calls on the phone a carer already carries: the most urgent on top, one tap to respond, loud or spoken alerts. iPhone and Android.

iPhone + AndroidPIN sign-inLoud or spoken
Live
EGWSoftware

Enterprise Gateway

The software head end: live calls and faults across every ward, response-time reports, display feeds, Olinqua/Ascom messaging, room-sensing integrations, uptime reporting and a BACnet feed — over Southerly hardware or read-only over a legacy system.

Head endReportsOlinqua · AscomBACnetLegacy mode
Live
WG-01Hardware

Ward Gateway

The ward-level interface board for the Enterprise Gateway: isolated tap and inject on the legacy loop, two isolated RS-485 buses, supervised I/O, dual 12 V with changeover, watchdog and RTC. Rev B.1 in production.

Legacy loop2 × RS-485Dual 12 VDIN rail
In development
EN-01Hardware

Edge Node

PoE ward controller: 8 relays, 8 supervised inputs, RS-485, clinical messaging over TAP, a built-in ward display that runs with no head end, Quiet Mode for silent nights, OTA firmware.

PoE8 relays · 8 inputsBuilt-in displayQuiet ModeRS-485OTA
Live
WD-01Hardware + software

Ward Display

A managed display appliance that turns a corridor TV, staff-base monitor or tablet into the ward call board — served on-device so it keeps showing calls with the network down, fed from the Edge Node over Ethernet with an out-of-band RS-485 backup link.

Corridor TV / tabletRuns offlineRS-485 backupLINK LOST state
Live
XM-02Hardware

PoE I/O Expansion Module

+8 relays and +8 supervised inputs over one PoE cable, anywhere on the ward LAN — Ethernet primary with an RS-485 backup link, so a duress button on the expander still reaches the board with the network down.

+8 / +8PoE 802.3afRS-485 backupFail-safe
Live
XM-01Hardware

RS-485 I/O Expansion Module

The same +8/+8 as a bus-only module on an Edge Node's RS-485, for the same cabinet or an existing bus run.

+8 / +8RS-485 onlyDIN rail
In development
CP-02Hardware

Call Point

Emergency and cancel in a sealed IP65 housing with RGB room lighting — on the supervised RS-485 room bus or an existing two-wire loop.

IP65RS-485 or legacy loopBluetooth
In production
ODL-01Hardware

Over-Door Light

Corridor light above each room door: a lit band around the edge that shows two calls at once, a laser-etched backlit room number, and Bluetooth staff location at the doorway.

24-zone RGBW bandBluetooth AoACat6 / 48 V
In development
LR-01Hardware

Light Relay

Mains latching relay for bed and over-door lights, driven from the call point with feedback and current sense.

LatchingCurrent senseRCM pending
Pending approval
WH-01Hardware

Ward Hub

1RU rack hub that powers and connects the ward: 16 isolated Cat6 segments of up to four rooms each, A/B 48 V from a 4-hour DC-UPS, per-port monitoring and fault isolation.

1RU rack16 isolated portsA/B 48 V
In development
RS-01Hardware + software

Room Sensor

Ceiling radar + thermal sensor that raises falls, bed exits and inactivity as nurse calls — no camera in the room. Supplied per room with messaging and reporting.

Radar + thermalNo cameraPer room / month60-day trial
Pilot
RS-01WHardware + software

Wireless Room Sensor

Radar fall, bed-exit and presence sensor that sends over LoRaWAN or Wi-Fi instead of a data cable, and can trip an Edge Node input directly. For rooms with power but no network point.

RadarLoRaWAN / Wi-FiEdge Node inputNo camera
Pilot
PL-01Hardware + software

Paging Link

Nurse calls to staff phones with every page confirmed: TAP to Ascom and other messaging platforms, acknowledgement checked, resent if refused, and a fault raised within seconds when paging stops. Connects to the existing ward controller without changing it.

Confirmed deliveryHeartbeatTAPExisting nurse callFire & BMS alarms4G remote support
In development
UPTIMESoftware

Uptime Report

Monthly availability report per site — gateway, link and controller-feed layers — for SLA evidence.

Part of Enterprise GatewayPDF / CSV
Live
—

Why it suits hospitals and aged care

Reports that answer the question

Response times by ward, shift and call type; repeat callers; faults with timestamps. Monthly uptime evidence for SLA meetings.

Calls reach the right phone

Native TAP integration with Olinqua and Ascom, heartbeat-supervised, so calls, faults and isolation events land on DECT and smartphones.

Silent by design

Quiet Mode moves routine call tones from the corridor to the pocket during quiet hours — supervised, logged, and fail-safe. Quiet nights without losing a call.

Resilient to attack

Runs on the ward LAN with no cloud; the display runs on the device itself. An out-of-band RS-485 backup link keeps calls on screen when the network is down or under attack; a LoRa link is in development.

AS 3811:2026, explained

The nurse call standard was rewritten in June 2026: fault supervision, cybersecurity, exportable reporting and a 30-minute UPS are now in scope. What it means for an existing system, and the honest state of ours against it.

No big-bang cutover

Run Southerly over the existing controller first, replace rooms as budget allows. Legacy displays and modules stay programmable throughout.

Open, documented, yours

MQTT and BACnet feeds, documented protocols, firmware you can update yourself. No licence keys that die when a vendor does.

Outside Australia?

Hospitals in Indonesia, Malaysia, the Philippines, Thailand, Singapore and Vietnam: supplied through local partners, or installed by our own team case by case.

Talk to an engineer, not a sales desk.

Tell us about the site, the system you have and what you need it to do. We'll come back with a straight answer and, where it fits, an accredited partner near you.

Contact Southerly →